Yale Assure Lock YRL216 Installation And Programming Instructions

Lever push button
Hide thumbs Also See for Assure Lock YRL216:

Advertisement

Yale Assure Lock Lever Push Button
®
®
Installation and Programming Instructions
®
(YRL216)
x2
#8-32 x 5/16"
Machine screws
x4
x2
#7 wood & #8-32
machine x 20mm
M4 x 22mm
Combination screws
Pan head machine
screws
AA Alkaline
Batteries
Battery Cover
Template
Key
Levers
Latch
Before you begin
Cylinder
DOWNLOAD
THE BILT APP
Optional
Network Module
Strike Plate
Battery Cover
for step-by-step installation
instructions & to register
your product
Keys
Interior Mounting Plate
Interior Lock
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO
THE PRODUCT AND VOID THE FACTORY WARRANTY
1
P/N
YRL LPBINSTL FUL
-
-
Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Yale Assure Lock YRL216

  • Page 1 Yale Assure Lock Lever Push Button ® ® Installation and Programming Instructions ® (YRL216) #8-32 x 5/16" Machine screws #7 wood & #8-32 machine x 20mm M4 x 22mm Combination screws Pan head machine screws AA Alkaline Batteries Battery Cover...
  • Page 2 Preparing to Install Tools Needed Standard Phillips Head Screwdriver Tools necessary only for new doors or adjusting existing prep. Template Tape Pencil Measure Drill Wood Mortise Chisel Utility Knife Level 2-3/8" through bolt posts default *Backset PULL 2-3/4" through bolt posts Note: Adjustment based on *2-3/8"...
  • Page 3 Checking Measurements 2-3/8" or 2-3/4" (60mm or 70mm) Backset 2-1/8" (54mm) Diameter 1-3/8" or 2-1/4" (35mm or 57mm) Door Thickness Door Prep Template YRL LPBINSTL FUL Rev A...
  • Page 4 Determining Door Handing Inswinging Door Outswinging Door Interior Left Hand Interior Right Hand Reverse Reverse Left Hand Right Hand Exterior Exterior Face a door swinging open Face a door swinging open away from you. toward you. If it swings open to the right, If it swings open to the right, it it is a right hand door.
  • Page 5 Preparing Door & Frame Necessary for new doors or adjusting existing prep. 2-1/8" Door Prep (54mm) Template Dia. 2-3/8" (60mm) 1" (25mm) 2-3/4" (70mm) Dia. Backset Drill holes 1/2 way through door then complete from other side to prevent splitting. Frame Frame Inside...
  • Page 6 Installing Latch & Strike Plate Right Hand Installation Shown Outside of Door Frame YRL LPBINSTL FUL Rev A...
  • Page 7 Installing Push Button Right Hand Installation Shown “TOP” mark must be on top surface and tailpiece in vertical position. Incorrect orientation will cause lock to fail. Outside of Right Hand Door Inside of Right Hand Door YRL LPBINSTL FUL Rev A...
  • Page 8 Installing Interior Mounting Plate Right Hand Installation Shown Inside of Right Hand Door Inside of Right Hand Door YRL LPBINSTL FUL Rev A...
  • Page 9 Attaching the Cable Assembly Right Hand Installation Shown Inside of Right Hand Door YRL LPBINSTL FUL Rev A...
  • Page 10 Installing Interior Lock Right Hand Installation Shown “Click” Inside of Right Hand Door YRL LPBINSTL FUL Rev A...
  • Page 11 Installing Exterior Cylinder Outside of Right Hand Door Latch Cylinder must be installed with bar away from latch. YRL LPBINSTL FUL Rev A...
  • Page 12 Installing Exterior Lever Outside of Right Hand Door Press pin while installing lever so lock is not damaged. Installing Interior Lever Inside of Right Hand Door Press pin while installing lever so lock is not damaged. YRL LPBINSTL FUL Rev A...
  • Page 13 Testing Thumbturn Operation Test with door open. Outside of Right Hand Door Outside of Right Hand Door If thumbturn operation test fails, check installation beginning with Step 3. YRL LPBINSTL FUL Rev A...
  • Page 14 Testing Key Operation Test with door open. Outside of Right Hand Door Outside of Right Hand Door If key operation test fails, check installation beginning with Step 6. YRL LPBINSTL FUL Rev A...
  • Page 15 Installing Optional Network Module Inside of Right Hand Door NOTE: If a network module was included with your lock, it is in a separate box with additional module installation instructions. YRL LPBINSTL FUL Rev A...
  • Page 16 Installing Batteries & Cover Inside of Right Hand Door Congratulations, you've installed the ® ® Yale Assure Lock Lever Push Button ( YRL216 Programming Instructions will help you customize your product. YRL LPBINSTL FUL Rev A...
  • Page 17 Testing Push Button Operation Test with door open. A Master Code must be created upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. See of Programming Instructions below.
  • Page 18 Resetting Lock to Factory Default Interior Lock Reset Button When resetting the lock, all user codes, including the Master code*, are deleted. All programming features are reset to original default settings. See “Factory Settings”. 1. Remove the battery cover and batteries. 2.
  • Page 19 Changing Lock: Replacing Cylinder 1.To Remove cylinder: See installation Step 6 "Installing Exterior Lever" and reverse appropriate actions to remove the exterior lever handle and cylinder. 2.To install new cylinder: A. Follow appropriate actions of installation Step 6 "Installing Exterior Lever"...
  • Page 20 Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not deadlock and/or lock signals failure via beeps a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt.
  • Page 21 Programming Instructions Speaker Master Code must be created before any further programming. Max User Codes = 250 with Network Module. Max User Codes = 25 without. YRL LPBINSTL FUL Rev A...
  • Page 22 Creating Master Code Creating a Master Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. Press Press Press Enter 4-8 digit Master Code.
  • Page 23 Creating User Codes Master code must be created first. *Max user codes = 250 with Network Module. Max user codes = 25 without. Enter Master code Press Press Enter 4-8 digit code Press Press Press Press (code flashes) Adding more User Codes: To end programming: Press Press...
  • Page 24 Unlocking Door with Code Enter Code Press Code Chart Duplicate if necessary PIN Code Management PIN Code (With Network Module Up to 250 Users) Master: User Name: YRL LPBINSTL FUL Rev A...
  • Page 25 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the locked padlock will appear on the screen. Audio Mode: The audio setting for code verification is set to...
  • Page 26 Feature Programming Through Menu Mode Using Master code* 1. Enter 4-8 digit master code* followed by key. 2. Enter digit corresponding to the function to be performed followed by the key. *The Master code must be created prior to any other programming of the lock. Master Code Setting User...
  • Page 27 Programming Troubleshooting Symptom Suggested Action Press each keypad button for response when pressed. • Lock does not respond – Check batteries are installed and oriented correctly (polarity) • door is open and in the battery case. accessible. Check batteries are in good condition; replace batteries* •...
  • Page 28 Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. Product Support Tel 1-855-213-5841 • www.yalehome.com Yale®, Yale Real Living® and Assure Lock® are registered trademarks of Assa Abloy Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.
  • Page 29 Yale Z -Wave Plus Module ® ® ® Installation and Programming Instructions Installing the Z -Wave Plus Module ® IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover and batteries. • Remove and/or insert Network Module.
  • Page 30 Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. YALE, with its unique global reach and range of products, is the world's favorite lock –...
  • Page 31 Z-Wave Plus System Integrators Guide Yale Assure Lever Lock YRL 216/226...
  • Page 32 Contents Yale Z-Wave Plus Info ............................3 Supported Command Classes ........................3 Association Table ............................4 Notifications Table ............................4 Configurable Parameters ..........................6...
  • Page 33 Yale Z-Wave Plus Info Manufacturer ID: Assa Abloy (0x0129) Z-Wave Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) Product ID: 0x0F00 Product Type ID: 0x800C YRL226-ZW2 (Touch Screen interface) 0x800B YRL216-ZW2 (Push Button Interface) Supported Command...
  • Page 34 Association Table Group ID Maximum Nodes Description Commands Command_Class_Battery, Battery_Report ; Command_Class_Notification, Notification_Report; Lifeline Command_Class_Configuration, Configuration_Report; Command_Class_Device_reset_locally, Device_Reset_locally_notification Notifications Table: Alarm Alarm Level Alarm Reports Description type (2Bytes) Master Code 0x0000 Master code was changed at keypad changed. 0xFB Master code was changed over RF 0x70 0x(0001-max User added...
  • Page 35 Enabled/Disabled then all users were affected. ** - The Yale lock also supports a 3 low battery alarm, too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery...
  • Page 36 Configurable Parameters Configuration Parameter Size Description Parameters Number Level control for YRL226, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 2 or Low Volume Silent mode on/off 1 1 byte Level Control for YRL216, 1 = Enabled, 3 = Disabled. Default is 1 or Enabled Auto Relock on/off 2 1 byte...

Table of Contents