Association Table

Group ID
Maximum Nodes
1
1

Notifications Table:

Alarm
Alarm Reports
type
Master Code
changed.
0x70
User added
User deleted
0x21
0xA1
Tamper Alarm
Manual Unlock
0x16
RF Operate Unlock
0x19
Keypad Unlock
0x13
Manual Lock
0x15
RF Operate Lock
0x18
Keypad Lock
0x12
Deadbolt Jammed
0x09
Lock Reset to
0x30
Factory defaults
Description
Command_Class_Notification, Notification_Report;
Lifeline
Command_Class_Configuration, Configuration_Report;
Alarm Level
Description
(2Bytes)
0x0000
Master code was changed at keypad
0xFB
Master code was changed over RF
0x(0001-max
User added. Alarm level = user slot number
users)
0x(0001-max
User was deleted. Alarm level = user slot number
users)
0x0001
keypad attempts exceed code entry limit
0x0002
front escutcheon removed from main
0x0001
by key cylinder or inside thumb-turn
0x0002
By Inside Button
0x0001
by RF module
0x(0001-max
Where Alarm level represents user slot number
users)
0x0001
by key cylinder or inside thumb-turn
0x0002
by one touch function (lock and leave)
0x0003
By inside button
0x0001
by RF module
0x (0001 max
Where Alarm level represents user slot number
users)
0x0001
Deadbolt motor jammed Locking
0x0002
Deadbolt motor jammed Unlocking
0x0000
lock was reset manually to factory defaults lock
0x0001
was reset over RF with a value of 0x01;
was reset over RF with a value of 0x02; reserved
0x0002
for future use
4
Commands
Command_Class_Battery, Battery_Report ;
Command_Class_Device_reset_locally,
Device_Reset_locally_notification