Non Access
0x26
0xA9
Low Battery Alarms
0xA8
0xA7
Auto Lock Operate
0x1B
Locked
Duplicate Pin-code
0x71
error
RF Module Power
0x82
Cycled
Disabled user
0x83
entered at keypad
Valid user but
0x84
outside of schedule
Daily Repeating
0x60
Schedule Set
Daily Repeating
Schedule
0x61
Enabled/Disabled
Year Day Schedule
0x62
Set
Year Day Schedule
0x63
Enabled/Disabled
All Schedule Types
0x64
Set
All Schedule Types
0x65
Enabled/Disabled
** - The Yale lock also supports a 3
Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery
alarm level before the product stops functioning.
0x(0001-max
A Non Access Code was entered at the lock.
users)
Where alarm level represents user slot number
0x(Current %)
Too Low to operate (Starting at 3.8V)
0x(Current %)
Critical Battery Level (Starting at 4.0V)
0x(Current %)
Low Battery (Starting at 4.2V)
0x0001
Auto re-lock cycle complete, locked.
Where Alarm level represents user slot number
Alarm generated in response to add user RF cmd.
This alarm is not generated when attempting to
0x (0001-max
add duplicate pin at the keypad. The lock simply
users)
denies
duplicate the master code will result in a 0x71
0x00 alarm report.
Power to RFM was restored, sent by RF module.
0x0001
when power is cycled.
0x (0001-max
A disabled user pin code was entered at the
users)
keypad. Alarm Level represents user slot number.
A valid user can be both a normal user and a Non-
0x (0001-max
Access user. If a non-access user is out of schedule
users)
this alarm will be sent instead of the non-access
alarm. Alarm Level represents user slot number.
Daily Repeating Schedule(s) were Set (Erased/Set)
User ID
for User ID specified in Alarm Level. If Alarm Level
= 0xFFFF then all users were affected.
Daily Repeating Schedule(s) were
enabled/disabled for User ID specified in Alarm
User ID
Level. If Alarm Level = 0xFFFF then all users were
affected.
Year Day Schedule(s) were Set (Erased/Set) for
User ID
User ID specified in Alarm Level. If Alarm Level =
0xFFFF then all users were affected.
Year Day Schedule(s) were Enabled/Disabled for
User ID
User ID specified in Alarm Level. If Alarm Level =
0xFFFF then all users were affected.
All Schedule Types were Set (erased/set) for User
User ID
ID specified in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
All Schedule types were enabled/disabled for User
User ID
ID specified in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
rd
low battery alarm, too low to operate. This alarm is sent out as a
5