Removable Display Remote Mounting - Eaton 12-110-1250y Operation And Installation Manual

1250w / 1500w / 1800w true sine wave inverter
Table of Contents

Advertisement

Removable display remote mounting

If desired, the inverter control panel can be removed and mounted remotely for remote control operation. A 25' communica-
tions cable is provided for this purpose.
The communications cable for optional mounting of the display should be at maximum 25 feet. Mounting the display flush
into a wall or panel requires an opening about 3.25in x 1.25in and 1.5in deep (8.3cm x 3.2cm and 3.8cm deep).
Mounting the display panel:
1.
The location for the panel should be dry, out of direct sunlight, free of corrosive fumes, and suitable for mounting an
electronic device.
2.
Draw the area to cut away with a pencil on the wall.
3.
Cut away the area and pilot-drill the mounting holes into the wall.
4.
Put the communication cable into the wall and route to the opening.
5.
Put the panel in the opening and fasten it into the wall securely.
6.
Route the cable to the inverter and insert the connection into the jack located in the front of the center cavity.
The communications cable should not be in parallel or in the same conduit as the AC and/or DC wires. If required, only cross
the wires at 90° angles of each other.
Insert connector carefully into jack. Forcing the connector into jack without proper alignment can cause permanent damage.
Eaton 1250W / 1500W / 1800W Inverter Operation and Installation Guide
IMPORTANT
Removable display remote mounting
IM SP180164 / Rev D
www.eaton.com
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents