Specifications
Table 15. Mechanical Specifications
Vibration
Table 16. Environmental Specifications
Temperature cycling
Thermal shock
Humidity
Altitude - operating
Altitude – non-operating
Table 17. Electromagnetic Specifications
Conducted immunity
Radiated RF immunity - bulk current
injection
Immunity to radiated RF
Load dump
Jump start test
Reverse polarity test
Table 18. Regulatory Requirements
UL458
CSA C22.2, No. 107.1
47 CFR FCC Part 15, Subpart B,
Class B 2016
12
Eaton 1250W / 1500W / 1800W Inverter Operation and Installation Guide
Per SAE J1455 Rev JAN2011,
Sec 4.10.4.2, Fig. 6-8, 22 hr/axis
Per SAE J1455, Rev. JUN2006,
Sec. 4.1, Test 4.1.3.1, Fig. 2B
Per SAE J1455, Rev. JUN2006,
Sec. 4.1, Test 4.1.3.2 Fig. 2C
Per SAE J1455, Rev. JUN2006,
Sec. 4.2, Fig. 4B
Per SAE J1455, Rev. JUN2006,
Sec. 4.9, Table 2
Per SAE J1455, Rev. JUN2006,
Sec. 4.9, Table 2
Per SAE J1113/3, Severity Level
L6 (0.5W)
Per SAE J1113/4, Class C,
Region 2, 80mA
Per SAE J1113/25 to 500 MHz
Per SAE J1113/27 500 MHz to
2 GHz
Per SAE J1455, Rev. JUN2006,
Sec. 4.11.2.2.1
Per SAE J1455, Rev. JUN2006,
Sec. 4.11.1
24 Vdc Applied to DC Terminals
Per SAE J1455 Sec. 4.11.1
–24 Vdc Applied to DC Terminals
Comply with the requirements of
the standard.
Comply with the requirements of
the standard.
Comply with the requirements of
the standard.
Must operate per specification
during and after the test.
Must operate per specification
during and after the test.
Must operate per specification
after the test.
Must operate per specification
during and after the test.
Must operate per specification
during and after the test.
Must operate per specification
after the test.
Manual restart required for
pulses 1, 2b, and 4
The inverter system should
restart without a fault.
The inverter shall present no
safety hazard. Internal fuses
will open in the inverter system,
requiring factory service for
replacement.
ETLus Mark
cETL Mark
FCC Mark