Outputs; Resource Usage; Execution Information; Table 86 Intervaltimercalibration: Output Values - Infineon SP37 Function Manual

High integrated single-chip tpms sensor with a low power embedded microcontroller and wireless fsk/ask uhf transmitter
Table of Contents

Advertisement

2.19.5

Outputs

Table 86
IntervalTimerCalibration: Output values
Register/ Address
R7
2.19.6

Resource Usage

Table 87
IntervalTimerCalibration: Resources
Type
Registers
SFR
Stack
1) Two additional bytes, not included here, are needed to call the library function
2.19.7

Execution Information

Table 88
IntervalTimerCalibration: Execution Time and Charge Consumption
Parameter
1)
Execution Time
1)
Execution Time
Charge
1)
Consumption
Charge
1)
Consumption
1) Values are obtained by extrapolation, not by characterization
ROM Library Function Guide
Type
Name
signed char
StatusByte
Used or Modified
R0, R1, R2, R3, R4, R5, R6, R7
ACC, B, CFG0, DPTR, ITPH, ITPL, LFOOTP, PSW, TCON, TH0, TH1, TL0, TL1,
TMOD
1)
2 Bytes
Symbol
Values
Min.
Typ.
t
1190
12Mhz
t
1130
XTAL
Q
1,23
12MHz
Q
1,60
XTAL
Tire Pressure Monitoring Sensor
Description
StatusByte:
0: Success
-1: No valid crystal frequency found in FLASH
-2: Input parameter out of range
Unit
Note / Test Condition
Max.
1680
µs
DIVIC = 00
12 MHz RC HF Oscillator
1570
µs
DIVIC = 00
2,56
µC
DIVIC = 00
12 MHz RC HF Oscillator
3,04
µC
DIVIC = 00
84
ROM Library Functions
, Clock Source is
H
Clock Source is XTAL
H
, Clock Source is
H
Clock Source is XTAL
H