Table 18
Meas_Pressure: Execution Time and Charge Consumption (cont'd)
Parameter
Charge consumption in
automatic range selection
Compensated Pressure result
with new raw temperature
measurement, 2 samples
Charge Consumption in
automatic range selection
compensated when supplied
with previously obtained raw
temperature value, 2 samples
Charge Consumption in
automatic pressure range for
each additional sample for
1)
averaging
1) The execution time and charge consumption for automatic range selection have been verified when the proper pressure
range is selected.
ROM Library Function Guide
Symbol
Min.
Q
–
autocomp,
new
1)
Q
–
autocomp,
prev
1)
Q
–
autosampl
e
Tire Pressure Monitoring Sensor
Values
Unit
Typ.
Max.
1,644
2,519
µC
1,196
1,873
µC
0,118
0,148
µC
40
ROM Library Functions
Note / Test Condition
DIVIC = 00
,
H
SensorConfig = 0481
,
H
SampleRate = 00
H
DIVIC = 00
,
H
SensorConfig = 0581
,
H
SampleRate = 00
H
SampleRate = 00
H
Only 1, 2, 4, 8, 16, 32, 64 samples
possible
Revision 1.0, 2011-12-15