2.4.7
Execution Information
Table 29
Meas_Acceleration: Execution Time and Charge Consumption
Parameter
Execution Time Compensated
with new raw temperature
measurement, 2 samples
Execution Time Compensated
when supplied with previously
obtained raw temperature
value, 2 samples
Execution Time Raw
(uncompensated) acceleration
result, 2 samples
Execution Time for each
additional sample for averaging
Charge Consumption
Compensated with new internal
raw temperature measurement,
2 samples
Charge Consumption
Compensated when supplied
with previously obtained raw
temperature value, 2 samples
Charge Consumption Raw
(uncompensated) acceleration
result, 2 samples
Charge Consumption for each
additional sample for averaging
ROM Library Function Guide
Symbol
Values
Min.
Typ.
t
–
909
comp,new
t
–
655
comp,prevt
t
–
304
RAW
t
–
64
sample
Q
–
1,611
comp,new
Q
–
1,125
comp,prev
Q
–
0,552
RAW
Q
–
0,135
sample
49
Tire Pressure Monitoring Sensor
Unit
Note / Test Condition
Max.
1015
µs
DIVIC = 00
SensorConfig = 0001
SampleRate = 00
767
µs
DIVIC = 00
SensorConfig = 0101
SampleRate = 00
334
µs
DIVIC = 00
SensorConfig = 0041
SampleRate = 00
71
µs
SampleRate = 00
2,516
µC
DIVIC = 00
SensorConfig = 0001
SampleRate = 00
1,87
µC
DIVIC = 00
SensorConfig = 0101
SampleRate = 00
0,809
µC
DIVIC = 00
SensorConfig = 0041
SampleRate = 00
0,17
µC
SampleRate = 00
SP37
ROM Library Functions
,
H
,
H
H
,
H
,
H
H
,
H
,
H
H
H
,
H
,
H
H
,
H
,
H
H
,
H
,
H
H
H
Revision 1.0, 2011-12-15