Control / Reference Value

10 Control / Reference Value
 410 Control Word
 411 Status Word
 484 Reference Frequency RAM [Hz]
 524 Reference Percentage RAM[%]
The frequency inverter can be controlled completely via the serial interface. The following parameters
and actual values are used for this:
Parameter
No. Name/Meaning
410 Control Word
411 Status Word
484 Ref. Frequency Value RAM [Hz]
524 Ref. Percentage RAM [%]
Control Word
With the
Reference Frequency RAM
With the
(data type Long [%]), the reference line value is sent. Via the
status of the frequency inverter is read out.
Note:
Control Word
410,
in the RAM of the frequency inverter. This is generally addressed via data set 0.
06/2010
0x0000
0x0000
-999,99
-300,00
410 (data type uInt), control commands are sent to the frequency inverter.
484 (data type Long [Hz]) or
Reference Frequency RAM
Setting
Min.
Max.
Factory Setting
0xFFFF
0xFFFF
999,99
300,00
Reference Percentage RAM
Status Word
Reference Percentage RAM
484 and
VABus Agile
Type
-
uInt
-
uInt
0,00
Long
0,00
Long
411 (data type uInt), the
524 are stored
524