Technical specifications
7.5 Hardware descriptions
Procedure
1. Navigate to the root directory of the DIO Setting tool as the Administrator user in the
command prompt window.
2. Enter the following commands to modify the registers:
– Set the specified General Purpose Input Output (GPIO):
– Show the specified GPIO:
– Show GPIO40-47:
3. According to the return value to determine whether the modification is succeed in the
command prompt window:
– 255: the modification fails.
– Others: the modification succeeds.
7.5.3

Internal interfaces

7.5.3.1

Overview of internal interfaces

Interface
M.2
72
GpioSetting [Parameter1] [Parameter2] [Parameter3](Optional)
Parameter
Value
number
1
GPIO number
2
Mode
3
Status
For example, Show GPIO47
GpioSetting
Position
Connector
Internal
SATA 3.0
M.2 2242 Key B (SATA)
Description
Range:
to
GPIO40
GPIO47
O: Output
I: Input
H: High
L: Low
GpioSetting [Parameter1] /S
: GpioSetting
GPIO47 /S
/ALL
Operating Instructions, 03/2019, A5E45491226-AA
Example
Set GPIO47 to Output High:
GpioSetting
GPIO47
Set GPIO47 to Output Low:
GpioSetting GPIO47
Set GPIO47 to Input:
GpioSetting
GPIO47
Description
SATA
SIMATIC IPC527G
O
H
O
L
I