Connecting The Power Supply - Siemens Simatic IPC527G Operating Instructions Manual

Table of Contents

Advertisement

3.3.3

Connecting the power supply

Note before you connect the device
Injuries to persons or damage to property when operated on an incorrect power supply
system
If you connect the device to an unsuitable power supply, the device receives voltages and
currents too high or too low.
Injuries to persons, malfunctions or a damage to the device can result.
Note the following information regarding the power supply system:
• The permitted nominal voltage of the device must correspond to the local mains voltage.
• Do not operate the device in non-grounded or impedance-grounded networks (IT
• Operate the device only in grounded power networks (TN networks in accordance with
Country-specific information
The power supply cable must conform to the safety regulations of the country in which the
devices are installed and bear the marks required in each case.
This device must be equipped with a safety-tested power cord which may only be connected
to a grounded shockproof power outlet. Use a flexible cable with the following features:
230 V supply voltage of the USA and Canada
● Type SJT with three conductors
● The connector must be compliant with NEMA 5-15.
● Conductor cross-section ≤ 18 AWG
● Cable length ≤ 4.5 m
120 V supply voltage of the USA and Canada
● Type SJT with three conductors
● The connector must be compliant with NEMA 5-15.
● Conductor cross-section ≤ 18 AWG
● Cable length ≤ 4.5 m
240 V supply voltage
● Type SJT with three conductors
● Conductor cross-section ≤ 18 AWG
● Cable length ≤ 4.5 m
SIMATIC IPC527G
Operating Instructions, 03/2019, A5E45491226-AA
WARNING
networks).
IEC 60364-1).
Installing and connecting the device
3.3 Connecting the device
29