Bosch T5600S 12 D 23 Training And Service Information page 34

Low nox instantaneous gas water heater / room sealed pressurized gas water heater for indoor installation
Hide thumbs Also See for T5600S 12 D 23:
Table of Contents

Advertisement

Access to
combustion
adjustments
Attention:
 Values of L0 (in P0), L1 (in P1) or L2 (in P2) are made to increase / decrease
burner power measured in mbar and according correspondent gas type / appliance
capacity indicated in correspondent manual.
 Values of A0 (in P0), A1 (in P1) or A2 (in P2) are made to increase / decrease fan
speed according info in the manual where a recommended value in indicated. To
Page 34 from 43
Technician Level
Go to
Ignition Burner Pressure
Adjustment of air flow without
change gas conditions
Adjustment of gas flow without
change air conditions
Maximum power burner
adjustment after components
replacement / maintenance /
gas conversions
Adjustment of air flow without
change gas conditions
Adjustment of gas flow without
change air conditions
Minimum power burner
adjustment after repairs /
maintenance / gas conversions
Adjustment of air flow without
change gas conditions
Adjustment of gas flow without
change air conditions
Table 15 – Combustion Power adjustments
6 720 887 547 "SM FP_ErP MPP Europe 2018/08 en"
Comments
press ok and select
P0 contains the fan speed
setting (A0) and gas power
(L0) needed for ignition
See installation manual for
recommended setting
See installation manual for
recommended setting
P1 contains the fan speed
setting (A1) and gas power
(L1) at maximum power
(depends on gas type /
model)
See installation manual for
recommended setting
See installation manual for
recommended setting
P2 contains the fan speed
setting (A2) and gas power
(L2) at minimum power
(depends on gas type /
model)
(depends on gas type /
model)
See installation manual for
recommended setting
See installation manual for
recommended setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents