Gas Power Adjustment Parameters
The adjustment of the appliance for minimum / maximum power operation can be needed under
following conditions:
-
Gas Conversion (see correspondent manual);
-
Gas valve / Fan Replacement;
-
Start up of unit when need to operate with Propane (LPG models are adjusted on
factory for Butane).
Following image indicates the measurement point to be used:
To keep the appliance in P1 (maximum power adjustment), is important to assure a minimum
water flow, otherwise the appliance will jump automatically to P2 (minimum power).
Table 14 – Minimum water flow needed to keep P1 in operation
Attention: due to this manual be master version for several markets, we recommend to always
refer to must updated info in installation manual provided with the unit.
Page 33 from 43
Pict.34 – Gas Manometer Connection
12 l Model: Flow > 4 l/min
15 l model: Flow > 5 l/min
17 l model: Flow > 6 l/min
6 720 887 547 "SM FP_ErP MPP Europe 2018/08 en"