-8
34.49
-7
32.93
-6
31.43
-5
30.03
-4
28.68
-3
27.40
-2
26.19
-1
25.04
0
23.95
1
22.92
Table 13 – NTC resistance values for Outlet Water NTC (Temperature Index table)
In order to ensure a correct start up of the appliance and a correct function after any
intervention on the appliance, the installation manual must be read and instructions and
main functions must be explained to the end user.

6. Service

When replacing the control unit, configurations need to be checked and set accordingly.
The parameters accessible to the user / installer are as indicated in following pictures.
Procedure to enter in Service Mode:
-
Press and hold "menu" for more than 5 seconds;
From this position and using the selection buttons "+" and "-", different service modes can
be assessed.
Attention:
Control units are supplied as spare part with following default values:
-
20 = Natural Gas (see P7 on AA menu)
-
15 = 15 liters appliance operation (see AP on AA menu)
Page 29 from 43
34
6.093
35
5.875
36
5.666
37
5.466
38
5.275
39
5.090
40
4.913
41
4.742
42
4.581
43
4.424
6 720 887 547 "SM FP_ErP MPP Europe 2018/08 en"
76
1.547
77
1.502
78
1.460
79
1.416
80
1.378
81
1.339
82
1.302
83
1.265
84
1.230
85
1.196