Installing the Lift Control Valve Solenoid Valve Coils
Groundsmaster
®
3280-D/3320
05138SL Rev B
1. Slide the coil assembly onto the hydraulic valve.
2. Install the nut onto the valve and torque the nut to 6.7 N∙m (5 in-lb).
Note: Do not overtighten the nut.
3. Connect the machine wire harness connector to the solenoid coil.