SPECIFICATIONS 8.0 EGTD
AC GENERATOR (Single Phase)
Single Phase
Voltage
Voltage regulation:
Frequency regulation:
Rating (Volts AC)
60
Hertz (1800 rpm)
8.0KW
50 Hertz (1500
rpm)
6.0KW
Generator Cooling
Air Requirements
{60 Hertz) at 1800 rpm
Engine Combustion
Engine Compartments
Cooling Air
Generator Compartment
Ambient Temperature
Recommendations
Brushless, four-pole, revolving field.
Pre-lubricated, single bearing design.
Reconnectable, single phase transformer
regulation (optional solid-state voltage
regulation).
120 or 120/240 Volts - 60 Hertz
230 Volts - 50 Hertz
±
5% no load to full load.
.5 Hertz (.6%) no load to full load.
120 Volts
66 Amps
120/240 Volts
66/33 Amps
230 Volts
27 Amps
175 • 200 cfm (4.95-5.66 cmm)
NOTE: Increase air supply 15% for 50
Hertz operation (1500 rpm)
42 cfm (1.19 cmm)
100-200 cfm (2.83-5.66 cmm)
122"F (50"C) maximum
NOTE: Forced ventilation should be
provided to maintain generator
compartment temperature below122'F (50"C)
SPECIFICATIONS 10.0 EGTD
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Voltage
Voltage regulation:
Frequency regulation:
Rating (Volts AC)
60 Hertz (1800
rpm)
10.0 KW
50 Hertz {1500 rpm)
7.5KW
Generator Cooling
Air Requirements
(60 Hertz) at 1800 rpm
Engine Combustion
Air Requirements
Engine Compartments
Cooling Air
Generator Compartment
Ambient Temperature
Recommendations
Brushless, four-pole, revolving field.
Pre-lubricated, single bearing design.
Reconnectable, single phase transformer
regulation (optional solid-state voltage
regulation).
120 or 1201240 Volts- 60 Hertz
230 Volts - 50 Hertz
±
5% no load to full load.
.5 Hertz (.6%) no load to full load.
120 Volts
83.3 Amps
1201240 Volts
83.3/41.6 Amps
230Volts
34.1 Amps
225 - 250 elm (5.66-6.37 cmm)
NOTE:
Increase air supply 15% for 50 Hertz
operation {1500 rpm)
42 elm (1.19 cmm)
100 - 200 cfm (2.83-5.66 cmm)
122•F (50"C) maximum
NOTE:
Forced ventilation shOuld be provided
to maintain generator compartment
temperature below122'F (50-G)
General - 3 Phase
10.0 KW • 60 Hertz
7.5 KW - 50 Hertz
Voltage - 3 Phase
(60 Hertz)
Voltage- 3 Phase
(50 Hertz)
Amperage • 3 Phase
(60 Hertz)
Amperage - 3 Phase
(50 Hertz)
Generator Cooling
Air Requirements
(60 Hertz) at 1800 rpm
Engine Combustion
Air Requirements
Engine Compartments
Cooling Air
Generator Compartment
Ambient Temperature
Recommendations
I~IWE!O#fiBEKE
l
Engtnss
&
Generators
42
Brushless six pole, revolving field. Sealed
lubricated single bearing design. 12 Lead
reconnectable for low voltage WYE, high
voltage Delta. Solid State voltage regulator
with protection circuitry.
Low voltage WYE
High voltage WYE
DELTA
High voltage WYE
DELTA
Low voltage WYE
High voltage WYE
DELTA
208vo!ts
480volts
240volts
380 volts
230vo!ts
35Amps
15
Amps
30Amps
High voltage WYE
14 Amps
DELTA
24 Amps
225- 250 cfm (5.66 • 6.37 cmm)
NOTE:
Increase air supply 15% for 50 Hertz
operation (1500 rpm)
42 cfm (1.19 cmm)
100 • 200 elm (2.83-5.66 cmm)
122"F (50•C) maximum
NOTE:
Forced ventilation should be provided
to maintain generator compartment
temperature below122'F (50"C)