Three Phase/Twelve Wire; Generator Ac Voltage Connections; Be Three Phase - Westerbeke 10.0 EGTD Operator's Manual

Electronically governed single and three phase marine diesel generators
Table of Contents

Advertisement

GENERATOR AC VOLTAGE CONNECTIONS
BE THREE PHASE
VOLTAGE REGULATORS
THREE PHASE CONNECTIONS
. The regulator
is
equipped with seven numbered terminals
(0 to 6) and their related brass jumpers. The illustrations
shown connection points and jumpers for the
3
phase con-
figuration of the generator. The sensing leads connect
between pin
#1
and pin
#2
on
the AC
terminal block and
connection
#2
and
#0
on the voltage regulator board.
NOTE:
Either Series configuration requires the installation of
a jumper on the regulator board between terminal Band 0.
170· 270
v
--.,
__ J60 Hz
AC TERMINAL CONNECTIONS
THREE PHASE 12 WIRE
l·N -120 VAC 10 60Hz
l·N -110 VAC 10 50 Hz
l-L-
480 VAC 30 60Hz
l·N- 277 VAG 10 60 Hz
LI
L2
N
PARAUEL WYE (STAR)
l·l- 208 VAC 30 60Hz
l·l-190 VAC 10 50 Hz
SERIES WYE (STAR)
l·l- 400 VAC 30 50 Hz
l·N- 230 VAC 10 50 Hz