Easy.IP.Setup.Software

Setting.IP.addresses.of.devices
Use Easy IP Setup Software to set the IP address of each device.
<Note>
With this software, the ROP and CCU are also displayed as cameras.
1..
Start.Easy.IP.Setup.Software.
A list of the devices connected with IP connections is displayed.
2..
Click.the.MAC.address.of.the.remote.camera,.ROP,.
or.CCU.you.wish.to.set,.and.then.click.the.[Network.
Settings].button.
<Note>
If there is an IP address conflict, the MAC addresses of the
corresponding cameras are displayed with drop shadows.
3..
Enter.each.of.the.network.items.and.then.click.[Save].
Set [Network Settings] to [Static IP].
Enter the setting information in [IPv4 address], [Subnet mask], and
[Default gateway].
Do not change any of the other settings.
34
<Note>
• If a firewall is activated, set the web browser or Easy IP Setup
Software to the "Allow a program through Windows Firewall" setting.
1. Open the control panel, and click [System and Security].
2. Click [Allow a program through Windows Firewall] of [Windows
Firewall].
3. Select the [Internet Explorer] or [EasyIpSetup] line, and then click
the [Change settings] button.
Check [Internet Explorer] or [EasyIpSetup].
4. Click the [OK] button.
• Setting of a CCU, remote camera, or ROP takes about 2 minutes to
complete after clicking the [Save] button. If the AC adapter or a LAN
cable is removed before the settings are complete, the settings will not
be applied. In such a case, configure the settings again.
• Set the network settings for the CCU from the menus of the CCU.
For details, refer the operating instructions for the CCU.
• Restart the CCU after changing of the settings is complete.
• If a firewall (including software) exists, allow access to UDP for all
ports.
• After the network settings have been configured, correct operation will
not be possible if an IP address is a duplicate of that of another device
which exists in the same network.
Set IP addresses that will not be duplicates.
• Do not configure the network settings from multiple instances of Easy
IP Setup Software at the same time.
Also, do not perform the auto IP setting operation of the AW-RP50 and
AW-RP120 remote camera controllers at the same time.
Doing so may result in the IP address settings becoming unknown.
• If you are using Microsoft
Windows
®
Windows Security Alert window may be displayed when you start Easy
IP Setup Software.
If that happens, click the [Unblock] button.
• If you are using Microsoft
Windows
®
the password for the administrator account when you start Easy IP
Setup Software.
If that happens, disable User Account Control from the Control Panel.
• As a security enhancement measure, Easy IP Setup Software stops
displaying the MAC address and IP address of a target remote camera
after about 20 minutes has elapsed since turning on the power.
For details on setting the display time, refer to the operating
instructions for the remote camera.
• Easy IP Setup Software cannot be used from a different subnet via a
router.