Operation.modes
The unit has a serial connection mode and an IP connection mode.
Serial connection mode
IP connection mode
Operation.
Connection.configuration
mode
Serial
Configuration with CCU connected with a
connection
serial connection
mode
Configuration with remote camera
connected with a serial connection
Configuration with camera recorder
connected with a serial connection
IP
Configuration with IP connections only
connection
mode
Configuration with a combination of a
CCU connected with a serial connection
and CCUs and remote cameras
connected with IP connections
Configuration with a combination of a
remote camera connected with a serial
connection and CCUs and remote
cameras connected with IP connections
Configuration with camera recorder
connected with a combination of a serial
connection and IP connection
Switching.between.serial.connection.mode.and.IP.connection.mode
Switch between serial connection mode and IP connection mode in ROP Setup Software. (→page 35)
When the settings are initialized (setup mode), the mode returns to serial connection mode (factory default state).
Serial connection mode
Possible to connect to a CCU, remote camera,
or camera recorder with a serial connection.
・An IP connection is not possible.
・You can set whether the control target is a
CCU or remote camera in setup mode.
Turn the power on.
Factory default state
In IP connection mode, you can switch control to any of up to 19 CCUs, remote cameras or camera recorders during operation.
In serial connection mode, you can only control one CCU, remote camera, or camera recorder during operation.
*
1
When serial connection mode
If an ROP configuration file that was saved to a memory card in IP connection mode is loaded, the operation mode becomes IP connection mode.
*
2
When IP connection mode
If an ROP configuration file that was saved to a memory card in serial connection mode is loaded, the operation mode becomes serial connection
mode.
4
The operation mode for use with a single CCU, remote camera, or camera recorder connected via a serial connection.
Only one CCU, remote camera, or camera recorder can be controlled. (The camera switching operation is not possible.)
The mode set at the time of shipment is serial connection mode.
The operation mode for use with CCUs, remote cameras and camera recorders used with IP connections.
A serial connection to a single CCU, remote camera, or camera recorder can be used at the same time as the IP
connections.
Up to 19 CCUs, remote cameras or camera recorders can be controlled. (The camera switching operation is possible.)
Use ROP Setup Software to configure various settings.
CCU
(1 device only)
(Connection not
possible)
(Connection not
possible)
(Do not connect)
(1 device only)
(Connection not
possible)
(Connection not
possible)
Switch to IP connection mode
in ROP Setup Software*
Return the operation mode to
serial connection mode in
ROP Setup Software*
Initializing the settings (setup mode) returns the mode to serial
connection mode (factory default state).
Serial.connection
Remote.camera
Camera.recorder
(Connection not
(Connection not
possible)
possible)
(Connection not
(1 device only)
possible)
(Connection not
possible)
(1 device only)
(Do not connect)
(Do not connect)
(Connection not
(Connection not
possible)
possible)
(Connection not
(1 device only)
possible)
(Connection not
possible)
(1 device only)
IP connection mode
Possible to connect to CCUs, remote cameras
.
1
and camera recorders with IP connections.
・IP connections can be used in combination
with a serial connection.
・You need to use ROP Setup Software to
configure various settings.
.
2
Use.of.
IP.connection
ROP.Setup.
Software
(Do not connect)
Not required
(Do not connect)
(Do not connect)
Required
(Total of up to 19
devices)
(Total of up to 18
devices)
(Total of up to 18
devices)
(Total of up to 18
devices)