Smart Rack Controller®
Thank you for purchasing Raritan's Smart Rack Controller (SRC). This product provides an ideal rack management solution which
features the following functions for data centers and server rooms:
Support for DX and DX2 environmental sensors, such as temperature and humidity sensors
Control and detection of a cabinet's door status (optional)
Asset management, which lists all IT devices
Important: Asset management feature and door handles (or SmartLock kit) are mutually exclusive. You cannot have both
devices connected simultaneously.
This Quick Setup Guide explains how to install and configure the SRC. For further details on using the SRC, access online help from
the application, or download the user guide from Raritan's
information on this release, see the latest release notes on the Support page.
Package Contents
The following lists the equipment shipped with SRC. If
anything is missing or damaged, contact the local dealer or
Raritan Technical Support for help.
One SRC device
Bracket pack and screws
Quick Setup Guide
Note: If you order any
Optional Accessories
are also shipped.
Optional Accessories
Part or all of the following equipment is shipped on demand
only.
Asset management strips and asset tags
Door handles or SmartLock kit
DX and/or DX2 environmental sensor package(s)
Warning: SRC does NOT support other Raritan
environmental sensor packages than DX and DX2 series.
QS Rule
Before You Begin
Prepare the installation site. Make sure the installation area
is clean and not exposed to extreme temperatures or
humidity. Allow sufficient space around the SRC for cabling
and equipment connections.
QS Rule
SRC Quick Setup Guide
SRC_QSG_0A_3.5.10_E  255-80-0063-00 RoHS
Support page
(
Rackmount
There are two ways to mount an SRC device, using the same
Raritan rackmount brackets.
(on page 1), they
1U Rackmount Method
 To mount SRC like a 1U device:
1. Align the two edge slots of the L-bracket with two of the
QUICK SETUP GUIDE
http://www.raritan.com/support/
1U Rackmount Method
(on page 1)
The SRC is mounted like a 1U device in the rack.
0U Rackmount Method
(on page 2)
The SRC is mounted like a 0U device in the rack.
screw holes on one end of the SRC device.
). For more detailed
1

Advertisement

Table of Contents
loading

Summary of Contents for LEGRAND Raritan Smart Rack Controller

  • Page 1 QUICK SETUP GUIDE Smart Rack Controller® Thank you for purchasing Raritan's Smart Rack Controller (SRC). This product provides an ideal rack management solution which features the following functions for data centers and server rooms:  Support for DX and DX2 environmental sensors, such as temperature and humidity sensors ...
  • Page 2: Connection Ports For Sensors, Door Handles, And Assets

    Connection Ports for Sensors, Door Handles, and 2. Screw the L-bracket to the device and ensure the bracket is fastened securely. Assets Optional Accessories If you purchase (on page 1), make sure you connect them to the correct port on the SRC, or it is likely damages may be caused to SRC and/or connected accessories.
  • Page 3: Feature 2: Cabinet Access Control

     That is, no connection or disconnection of door handles Connecting Environmental Sensors (Optional) when they are powered.  An SRC provides the SENSOR port for connecting Raritan DX The maximum cabling length for door handles or or DX2 environmental sensor packages so that you can SmartLock kit is 29 feet (9 meters).
  • Page 4: Feature 3: Asset Management

     SRC door handle ports and terminals: Component Function   Numbers in the following diagram ( ) correspond to contact detectors/switches for detecting the the numbers in the previous section's table. closure sensor door open/closed status. terminals Contact closure detectors are OPTIONAL.
  • Page 5 programmable tags. The only difference is that Introduction to Regular Asset Strips programmable asset tags allow you to customize each tag's ID or barcode number while non-programmable ones have Each tag port on the regular asset strips corresponds to a factory default ID or barcode numbers, which you cannot rack unit and can be used to locate IT devices in a specific change.
  • Page 6: Connecting Src To Power

    strips. For detailed information, refer to the user 2. Vertically attach the asset strip assembly to the rack, next documentation accompanying Raritan asset strips. to the IT equipment, making each tag port horizontally align with a rack unit.  Composite asset strips: The asset strips are automatically attracted to the rack ...
  • Page 7: Connecting Src To Your Network

    You can connect only one or both inlets to proper power Using the Front Panel Display sources. The SRC front panel display is similar to the diagram below. 1. Connect each SRC to an appropriately rated branch circuit. Refer to the label or nameplate affixed to your SRC for appropriate input ratings or range of ratings.
  • Page 8: Appendix A: Configuration Via A Mobile Device Or Pdview

      Android Choose Device Settings > Date/Time to configure the SRC : Use an USB OTG adapter cable. with the proper date and time or synchronize it with an 2. Connect the mobile device to the appropriate USB port on NTP server.
  • Page 9: Appendix C: More Information

    RJ-45 Cap in the EXPANSION Port Wi-Fi LAN adapters Supported 802.11 protocols SRC has a cap plugged into its EXPANSION port when shipping out of the factory. This port is reserved for future use Edimax EW-7722UnD A/B/G/N and does NOT function. It is suggested to keep the cap TP-Link TL-WDN3200 v1 A/B/G/N plugged continuously.

Table of Contents