INNER SAFETY AIR FILTER ELEMENT
EXCHANGE
− remove the wing nut of inner safety air
filter element
− remove the safety air filter element
Inner safety air filter element can
not be regenerated!
It must be exchanged in the following
cases:
- if the main air filter element is damaged
th
- after 5
maintenance of air cleaner
- minimally once per 2 years
MAINTENANCE INSTRUCTIONS
S21
AIR FILTER ELEMENT REASSEMBLY
Be careful at the air filter element re-
assembly:
- keep the contact surfaces clean
- air
filter
elements
deformed and must not vibrate after
assembly
- rubber sealing must be fitted properly
round the complete circumference, the
proper tightness of the complete
cleaner must be assured after reas-
sembly of air filter cover
38
S28
CLOGGING INDICATOR RESET
Reset the clogging indicator after
dry air cleaner maintenance.
− push the push button on the indicator
must
not
be
body (2a)
− you will mechanically release the in-
dicator lock of red field indicating
clogging
− indicator is again in function (2b)
S8