Item number
Item name
710
INTERNAL VIDEO SIGNAL
GENERATOR
713
VIDEO SETUP REFERENCE
LEVEL
Sub-item
OUTPUT
LEVEL
715
VIDEO GAIN CONTROL
716
CHROMA GAIN CONTROL
717
CHROMA PHASE CONTROL
718
SETUP LEVEL (59.94i/59.94P/
29.97P mode)/BLACK LEVEL (50i/
50P/25P mode)
719
SYSTEM PHASE SYNC
720
SYSTEM PHASE SC
723
INPUT VIDEO BLANKING
Sub-Item
1
ALL LINE
2...10 LINE 12
...
LINE 20
2...15 LINE 9
...
LINE 22
Menu items in the 700s, relating to video control
Settings
Select the test signal to be output from the internal test signal generator.
When V INPUT on the P1 VIDEO page of the function menu is set to
"SG", the internal test signal generator operates to output the selected
test signal. This signal can also be recorded.
CB75 (75% Color Bars): 75% color bar signal
CB100 (100% Color Bars): 100% color bar signal
MLTBS (Multi Burst): Multi-burst signal
10STEP (10 steps): 10-step signal
PLSBR (Pulse and Bar): Pulse and bar signal
RAMP (Ramp): Ramp signal
BLACK (Black): Black signal
ARIB CB (ARIB Color Bars): ARIB color bar signal, modify width, 100%
Note
ARIB CB cannot be specified when SD recording is selected. If ARIB CB
is selected, the selection is changed to CB75 (75% Color Bars).
Set the video setup amount to be added to the composite output signal (in
59.94i/59.94P/29.97P mode only).
In 59.94i/59.94P/
Add the setup level selected by this item to the output signal.
29.97P mode (UC)
0.0%, 7.5%
In 59.94i/59.94P/
Add the setup level selected by this item to the output signal.
29.97P mode (J)
0.0%, 7.5%
Adjust the video output level.
–2048 to 0 to 848
Adjust the chroma output level.
–2048 to 0 to 848
Adjust the chroma phase.
–128 to 0 to 127
Adjust the setup level (black level).
–272 to 0 to 272
Adjust the output signal sync phase.
–128 to 0 to 127
Adjust the output signal subcarrier phase.
0 to 511
a)
Switch blanking on or off for lines in the vertical blanking interval of input
video signals. Lines can be specified individually. Y/C signals and odd/
even fields are blanked simultaneously.
Blanking in recorded signals is carried out according to these settings.
- - -: Specify the blanking for each line separately.
blnk (blank): Regardless of the settings of other sub-items, blank all lines
which can be specified in this menu item.
thru (throu): Regardless of the settings of other sub-items, switch
blanking off for all lines which can be specified in this menu item.
In 59.94i/59.94P/
Specify blanking for lines 12 to 20.
29.97P
blnk (blank): Switch blanking on.
mode
thru (throu): Switch blanking off.
In 50i/50P/25P
Specify blanking for lines 9, 322 to 22, and 335.
mode
blnk (blank): Switch blanking on.
thru (throu): Switch blanking off.