1
7.
2
Launching a setup
Unlock the sensor to enter into adjustment session.
To launch an assisted setup
recommended after mechanical adjustments of the IR sensor
module.
recommended once after the first installation
To launch a setup
recommended after change of parameters by remote control
LED display during sensor assisted setup
Setup process active:
RED/GREEN
LED
alternating
7.
1
3
Additional remote control adjustments
SAFETY OUTPUT
REDIRECTION
0
no redirection
1
transfer presence detection
to motion output
HOLD TIME
0-9
0 (0.5s) > 9 (9s)
DETECTION
MODE
1
bidirectional mode
2
unidirectional mode
3
unidirectional mode with MTF
ACTIV8 THREE PULSE
After finishing the setup process, the sensor shows the following behaviour:
RED LED flashing quickly
RED LED continuously on
ORANGE LED continuously on
No LED turns on
0
0
2
RED LED
flashes slowly
RED/GREEN
LED
alternating
This setup is only effective if the relay output (opening) has been wired to the door
controllers opening impulse input. This is required to create a door opening/closing
cycle.
RED/GREEN
LED
alternating
The sensor 'sees' the door movement and can not finish its setup.
The sensor signals a faulty IR monitoring.
The sensor encounters signal saturation
(ex. due to highly reflective floor).
The sensor successfully finished its setup.
The sensor performs a door opening and closing
cycle to check the influence of the door leaves to
the safety curtains. See Troubleshooting if RED
LED flashes quickly after setup.
The sensor only takes a new reference picture.
INSTALLATION
CONFIGURATION
MOUNTING
HEIGHT
1
low
2
high
3
low
4
high
1
IMMUNITY
1
detection of quasi presence
2
normal
3
increased
4-9
additional increased
immunities
2
7
7
PULSE
FREQUENCY
low
low
high
high
5/8

Advertisement