7
Remote control adjustments (only if factory values do not match)
Unlock the sensor to enter into adjustment session
(see p.5 for info on the use of an access code)
To change the value of a parameter
(ex. IR curtain immunity)
To change any other parameters
(ex. Output Configuration)
To check the value of a parameter
(ex. Max duration of presence detection)
Lock the adjustment session and go back to normal function
1
7.
1
Important remote control adjustments
UNLOCK
CHECK VALUES
LOCK
SENSITIVITY
0-9
0 (min) > 9 (max)
IR CURTAIN
IMMUNITY
1
normal
2
increased
3
rain mode
4
snow mode
5
snow mode enhanced
ACTIV8 THREE PULSE
7
1
RED LED
flashes slowly
RED LED
RED LED
flashes quickly
flashes slowly
RED LED
RED LED
flashes quickly
flashes slowly
RED LED
flashes quickly
Number of flashes = value of this parameter
LED OFF
2
0
1
2
3
4
5
6
1
6
...
GREEN LED
RED LED
flashes slowly
NUMBER
OF IR
CURTAINS
1
1 curtain
(curtain closest to door)
2
2 curtains
3
2
curtain in dynamic mode
nd
MAX. DURATION
OF PRESENCE
DETECTION
30 seconds
1 minute
2 minutes
5 minutes
10 minutes
20 minutes
60 minutes
SETUP
launch
setup
launch
assisted setup
restore
factory settings