Download Print this page
BEA ACTIV8 THREE F Instructions

BEA ACTIV8 THREE F Instructions

Opening & safety sensor for automatic sliding doors in escape routes

Advertisement

Quick Links

LED-SIGNALS
The ORANGE LED
The sensor goes into
fl ashes every second.
security mode.
The ORANGE LED
The sensor signals
an internal fault.
fl ashes 1 x.
1
The ORANGE LED
Irregularities in the
fl ashes 2 x.
power supply
2
The sensor receives
The ORANGE LED
fl ashes 4 x.
not enough IR-energy.
4
The ORANGE LED
The sensor receives
fl ashes 5 x.
too much IR-energy.
5
The radar sensor output is
The ORANGE LED
faulty.
fl ashes 6 x.
6
The sensor is disturbed.
The ORANGE LED
The radar sensor encounters
fl ashes 7 x.
7
a hardware problem.
The ORANGE LED
The sensor encounters
is on.
a memory problem.
The RED LED fl ashes
The sensor sees the door
quickly after an
during the assisted setup.
assisted setup.
The sensor vibrates.
The RED LED
lights up
sporadically.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
The sensor is disturbed by
The GREEN LED
rain and/or leaves.
lights up
sporadically.
Ghosting
The sensor vibrates.
The sensor sees the door
or other moving objects.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
BEA hereby declares that the ACTIV8 THREE F is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, November 2010
Jean-Pierre Valkenberg, Authorized representative
The complete declaration of conformity is available on our website: www.bea.be
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA.BE
1
Cut and restore power supply.
1
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
2
1
Check power supply.
2
Check wiring.
1
Use the 1 m prism if possible.
Check the angle of the IR-curtains.
2
Use a low energy prism if possible.
1
Check the angle of the IR-curtains.
2
1
Replace sensor.
1
Change radar antenna angle.
Replace sensor.
1
1
Cut and restore power supply.
2
If orange LED lights up again, replace sensor.
1
Check the angle of the IR-curtains.
2
Launch a new assisted setup.
Attention: Do not stand in the detection fi eld!
Check if the sensor is fastened fi rmly.
1
2
Check position of prism and cover.
1
Launch an assisted setup and adjust the IR angle.
1
Choose a different frequency by remote control.
1
Increase the IR-immunity fi lter to value 2 or 3.
Increase radar-immunity fi lter by remote control.
1
Change radar antenna angle.
1
1
Check if the sensor is fastened fi rmly.
2
Check position of cable and cover.
1
Remove the objects if possible.
2
Change radar antenna.
3
Change radar fi eld size (sensitivity).
Check connections to test output.
1
If your door controller is not able to test the sensor,
2
connect the red and blue cable to power supply.*
1
Check output confi guration setting.
Switch value 1 (P) to 2 (A) or 2 to 1 by remote
2
control.
*excludes DIN18650-conformity of the door system
Please keep for further use
Designed for colour printing
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer. The
manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
DESCRIPTION
4
3
2
1
1.
IR-prism
(2 m)
2.
radar antenna
(wide fi eld)
3.
radar antenna
(narrow fi eld)
4.
cover
TECHNICAL SPECIFICATIONS
Supply voltage:
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
Power consumption:
< 3 W
Mounting height:
1.8 m to 4 m
(< 3 m to enable DIN 18650-conformity)
Sensitivity of the test input:
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
Temperature range:
-25 °C to +55 °C
Degree of protection:
IP54
Expected lifetime:
5 years
Norm conformity:
R&TTE 1999/5/EC; EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «d» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
GREEN
LED
Detection mode:
Motion
Min. detection speed: 5 cm/s
Response time on test request:
Technology:
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
Angle:
From 15 ° to 50 ° vertical (adjustable)
Hold time output signal:
0.5 s to 9 s (adjustable)
Output:
Transistor (optocoupled transistor)
Max. output current:
Max. switching power: 42 V DC
State "motion detection":
output signal not pulsed
State "no motion detection":
output signal pulsed (f = 100 Hz +/-10%)
ACTIV8 THREE F
Opening & safety sensor
for automatic sliding doors
in escape routes
5.
push buttons
6.
IR-curtain ajustment screw
7.
main connector
(to be operated from SELV compatible power supplies only)
RED
LED
Presence
Typical response time: <128 ms (max. 500 ms)
Typical: < 15 ms (max. 25 ms)
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24 or 12 by curtain
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
0.3 s to 1 s (not adjustable)
Transistor (optocoupled transistor)
100 mA
Max. output current:
100 mA
Max. switching power: 42 V DC
All values measured in optimal conditions.
5
6
7

Advertisement

loading

Summary of Contents for BEA ACTIV8 THREE F

  • Page 1 (f = 100 Hz +/-10%) All values measured in optimal conditions. BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA.BE...
  • Page 2 ACTIV8 THREE F ACTIV8 THREE F MOUNTING & WIRING SETTINGS (by push buttons and/or remote control) GREEN RADAR FIELD SIZE , S ... , XS 12-24 V POWER SUPPLY (SENSITIVITY) BROWN AC-DC YELLOW MONITORED SHORT PUSH RIGHT: SHORT PUSH LEFT:...