BEA ACTIV8 THREE PULSE User Manual page 3

Combined radar opening and active infrared safety sensor for escape route doors
Table of Contents

Advertisement

5
1
Width of IR presence sensing field: choice of prism
24 overlapping spots
6
1
Depth of IR presence sensing field: angle of IR-module (negative angle available)
Keep a minimum distance of 5cm between
the door and first curtain.
When mounting one sensor on each side of the door above a highly reflective threshold, select different frequencies to
avoid crosstalk between the sensors.
ACTIV8 THREE PULSE
2 curtains of
12 overlapping spots
(no gaps)
To reduce the distance between curtain and door, turn
the screw clockwise. To increase the distance, turn the
screw counterclockwise. The pin indicates the angle.
Make sure to introduce the prism
2 curtains of
into the guiding grooves
(no gaps)
in front of the lenses and not into
the cover!
If installed at a mounting height
of 3 m or more, use the narrow
prism.
Use the Spotfinder to locate and
adjust the position of the curtains.
5