4.4 CFast Operational Check

4.4.1 SMART

Confirm that S.M.A.R.T. information can be retrieved.
root@BX-830:~# apt-get install smartmontools
root@BX-830:~# smartctl –a /dev/sda
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-24-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model:
HAGIWARA SOLUTIONS LFD10S-032GC(A00AFS
Serial Number:
HSS32G15031900004029
Firmware Version: 20140822
User Capacity:
32,212,647,936 bytes [32.2 GB]
Sector Size:
512 bytes logical/physical
Rotation Rate:
Solid State Device
Device is:
Not in smartctl database [for details use: -P showall]
ATA Version is:
ATA8-ACS (minor revision not indicated)
Local Time is:
Wed Jan 10 23:32:32 2018 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00)
Total time to complete Offline
data collection:
Offline data collection
capabilities:
SMART capabilities:
Error logging capability:
BX-830 Ubuntu 14.04 Desktop 64bit Operational Check Manual
Offline data collection activity
(
0) seconds.
(0x00)
(0x0002)
Does not save SMART data before
(0x00)
Error logging NOT supported.
was never started.
Auto Offline Data Collection: Disabled.
Offline data collection not supported.
entering power-saving mode.
Supports SMART auto save timer.
No General Purpose Logging support.