Note
・ The unit can be magnetically secured by ZN9-WM01-S magnets (sold separately) placed
in the screw holes. (Tightening torque: 0.4 N/cm to 0.6 N/cm)
・Mount the unit on a location where mechanical shock is not applied when mounting it
with magnets.
・Be careful not to allow the sensor head and cable to apply pressure to the
magnet-mounted unit.
Flat-head Screws: M3 x 6
Mounting Magnets
(3)
Mounting with Screw Hook Holes
Two screw hook holes are provided below the convex section of the upper unit area, which
allows fixing the unit on the wall or other vertical surface. (Refer to the Appendix: Installation
Diagram for the screw hooking hole dimensions.)
Fix M3 screws on the wall and hook the unit on the screw heads through the holes. Allow a
distance of 2.5 mm or more between the bottom of the screw heads and the wall surface.
Important
Firmly hold the unit with a hand to insert or remove the SD memory card if the unit is
mounted by hooking. Otherwise the unit may drop on the floor and be damaged.
2.5 mm or more
Enlarged Hook Screw Section View
3-29
3. Check and Preparation