During Operation - Lenze g500 Series Mounting Instructions

Bevel gearbox / bevel gearbox with three-phase ac motor
Hide thumbs Also See for g500 Series:
Table of Contents

Advertisement

6
Commissioning and operation

During operation

Please check the following:
¯ Drive function - machine function assignment
¯ The direction of rotation of the drive shaft
All sizes except for G50BB124, 3−stage
Fig. 11
Rotating direction of drive shaft
6.4
During operation
¯ Warming
If operating conditions are unfavourable (e.g. high input speed, small ratio, vertical
mounting position, high ambient temperature, ...), the gearboxes may heat up more.
Temperature
> 70 °C
> 80 °C
> 100 °C
Tab. 9
Housing temperature
During operation, check the drive periodically and take special care of:
¯ changes compared to normal operation, like
unusual noise, stronger vibrations or increased temperatures,
leakages,
loose fixing elements,
the condition of the electrical cables.
¯ In the event of faults:
shut down the drive,
check the troubleshooting table.
If the fault cannot be remedied, please contact the Lenze customer service.
46
Only G50BB124, 3−stage
Measures
Apply covers and warning labels
Gearboxes with mineral oil (CLP) or for standard shaft sealing ring,
¯
Use synthetic oil,
¯
Provide for better cooling,
¯
It may be necessary to contact Lenze
Gearboxes with synthetic oil (CLP HC) and FKM shaft sealing ring
¯
Provide for better cooling,
¯
It may be necessary to contact Lenze
Lenze ¯ MA 12.0014 ¯ 5.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents