Safety instructions
Residual hazards
2.4
Residual hazards
Protection of persons
¯ Risk of burns!
–
Hot surfaces up to 140 °C during operation! Provide protection against contact.
¯ Highfrequency voltages can be capacitively transferred to the motor housing
through the inverter supply.
–
Earth motor housing carefully.
¯ Risk of injury due to rotating shaft!
–
Before working on the drive system, ensure that the motor is at a standstill.
¯ Danger of unintentional starting or electrical shocks!
–
Connections must only be made when the equipment is deenergised and the
motor is at standstill.
–
Installed brakes are no fail−safe brakes.
¯ Dangerous voltages at the power terminals, even if the plug is removed: residual
voltage >60 V!
Motor protection
¯ Installed thermal detectors are no full protection for the machine.
–
If required, limit the maximum current, parameterise the controller such that it
will be switched off after some seconds of operation with I > I
there is the danger of blocking.
–
Installed overload protection does not prevent an overload under any
conditions.
¯ Installed brakes are no fail−safe brakes.
–
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
¯ Fuses are no motor protection.
–
Use current−dependent motor protection switches at average operating
frequency.
–
Use installed thermal detectors at high operating frequency.
¯ In the case of permanent−magnet motors, too high torques cause
demagnetisation.
–
The maximum torques according to catalogue must not be exceeded.
¯ If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.
¯ Design with plug:
–
Never disconnect plug when energised! Otherwise, the plug can be destroyed.
–
Switch off power supply and inhibit controller prior to disconnecting the plug.
Fire protection
¯ Fire hazard
–
Prevent contact with flammable substances.