Siemens SIMATIC IPC127E Operating Instructions Manual page 54

Hide thumbs Also See for SIMATIC IPC127E:
Table of Contents

Advertisement

Technical specifications
6.1 General technical specifications
Electromagnetic compatibility
Immunity with regard to conducted
interference on the supply lines
Noise immunity on signal lines
Immunity to discharges of static
electricity
Immunity to RF interference
Magnetic field
Main circuit board
Processor / main memory
Drive, memory medium
Solid State Drive
Floppy and CD-ROM drive
USB stick
Only to device USB port, not via USB hub
1
Graphics
Graphics controller
Graphics memory
Resolution, graphics memory
54
± 2 kV according to IEC 61000-4-4; burst
± 0.5 kV according to IEC 61000-4-5; surge symmetrical
± 1 kV according to IEC 61000-4-5; surge asymmetrical
± 1 kV to IEC 61000-4-4; Burst; Length < 3 m
± 2 kV in accordance with IEC 61000-4-4; Burst; length > 3 m
± 2 kV in accordance with IEC 61000-4-5; Surge; length > 30 m
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
10 V/m, 80 ... 2 GHz,
80% AM according to IEC 61000-4-3
3 V/m, 2 ... 6 GHz, 80% AM according to IEC 61000-4-3
10 V, 10 KHz ... 80 MHz, 80% AM according to IEC 61000-4-6
100 A/m, RMS value 50/60 Hz in accordance with IEC 61000-
4-8
Intel Atom E3930, 2 cores/2 threads, 2 GB RAM
Intel Atom E3940, 4 cores/4 threads, 4 GB RAM
Intel Atom E3930, 2 cores/2 threads, 2 GB RAM; TPM
Intel Atom E3940, 4 cores/4 threads, 4 GB RAM; TPM
LPDDR4 memory
32 GB SSD
64 GB SSD
128 GB SSD
External, can be connected via USB port
External, can be connected via USB port
Integrated Graphic Controller
Up to 512 MB, shared memory
DisplayPort resolution:
640 × 480 pixels to 4096 × 2160 pixels
Up to 512 MB graphics memory is taken from main
memory, UMA, dynamic
Operating Instructions, 01/2019, A5E44296915-AA