Watchdog (Wd) - Siemens SIMATIC IPC127E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC127E:
Table of Contents

Advertisement

4.3.1.3

Watchdog (WD)

Configuration
You configure the watchdog with the DiagBase or DiagMonitor software.
Function
The watchdog is able to monitor system runtime and informs the user about the different
reactions that are triggered if the system does not respond to the watchdog within the
specified monitoring time.
A watchdog alarm is retained after a restart and is reset and logged by the DiagBase or
DiagMonitor software. The watchdog configuration is retained in the process.
Watchdog reactions
The following reactions can occur if the watchdog is not addressed within the set time:
Option
Reset on
Reset off
Restart
Shutdown
NOTICE
"Reset on" option
The "Reset on" option immediately triggers a hardware reset that may result in loss of data
under Windows and damage to the installation.
Watchdog monitoring times
The hardware supports the following times:
● Setting range from 1.2 s to 613.8 s; step width: 0.6 s; accuracy: ± 0.6 s
Set the monitoring times in SIMATIC Diagnostics Management as integer in the range from 4
to 64 seconds.
Note
Contact Customer Support for a detailed description of the Watchdog functions.
SIMATIC IPC127E
Operating Instructions, 01/2019, A5E44296915-AA
Reaction
Executes a hardware reset when the watchdog expires
Executes no action when the watchdog expires
Restarts the operating system when the watchdog expires
Shuts down the operating system when the watchdog expires
Commissioning the device and device functions
4.3 Extended device functions
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents