Connection examples for redundant I/Os
F.17 SM 322; DO 16 x DC 24 V/10 mA [EEx ib], 6ES7 322–5SD00–0AB0
F.17 SM 322; DO 16 x DC 24 V/10 mA [EEx ib], 6ES7 322–5SD00–0AB0
The diagram below shows the connection of an actuator to two SM 322;
DO 16 x DC 24 V/10 mA [EEx ib]. The actuator is connected to channel 0. Suitable diodes
include types of the series 1N4003 ... 1N4007, or any other diode with U
I_
>= 1 A
F
Figure F-17
352
Example of an interconnection with SM 322; DO 16 x DC 24 V/10 mA [EEx ib]
>= 200 V and
_r
System Manual, 09/2007, A5E00267695-03
S7-400H