STAPLE LOADING
2
Slider Unit
1
Push the click lever.
2
Pull out the slider unit.
A set of staples
(Insert it with the square
feet of staples up)
Magazine
3
Insert a set of staples into the magazine with the point of
staples up.
Slider Unit
4
Press the slider unit to set the click lever securely.
TEST OPERATION
1
2
3
Click Lever
4
1
AIR HOSE CONNECTION
Connect the air chuck to the air plug.
When connecting the air chuck, do not point the staple
discharge outlet at any part of your body or at another
person, and do not touch the trigger.
DRIVING FASTENERS
NOTE :
This tool is shipped with SEQUENTIAL TRIP selected.
SEQUENTIAL TRIP
The Sequential Trip requires the operator hold the tool against
the work before pulling the trigger.
This makes accurate fastener placement easier, for instance on
framing, toe nailing and crating applications.
The allows exact fastener location without the possibility of
driving a second fastener on recall, as described under "Contact
Trip".
The Sequential Trip Tool has a positive safely advantage be-
cause it will not accidentally drive a fastener if the tool is con-
tacted against the work or anything else-while the operator is
holding the trigger pulled.
Switching SEQUENTIAL TRIP to CONTACT TRIP
ALWAYS-disconnect air supply before switching the trig-
gering method.
Click Lever
7
Adjust the air pressure at 5 bar (70p.s.i.) and connect the
air supply.
Without touching the trigger, depress the contact arm
against the work-piece.
Pull the trigger (The tool must fire the fastener.)
With the tool off the work-piece, pull the trigger.
Then depress the connect arm against the work-piece.
(The tool must fire the fastener.)
Adjust the air pressure as much as the lowest possible
according the length of fastener and the hardness of work
piece.
WARNING
WARNING