Technical documentation
Model
Type of heat pump
Low-temperature heat pump
Integrated immersion heater for additional heat
Heat pump combination heater
Climate
Temperature application
Applied standards
Rated heat output
Declared capacity for space heating at part load and at outdoor temperature
Tj
Tj = -7 °C
Tj = +2 °C
Tj = +7 °C
Tj = +12 °C
Tj = biv
Tj = TOL
Tj = -15 °C (if TOL < -20 °C)
Bivalent temperature
Cycling interval capacity
Degradation coefficient
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
Sound power level, indoors/outdoors
Annual energy consumption
Contact information
52
Chapter 11 |
Technical data
Air-water
Exhaust-water
Brine-water
Water-water
Yes
No
Yes
No
Yes
No
Average
Cold
Average (55 °C)
EN14511 / EN14825 / EN12102
Prated
5.3
kW
Seasonal space heating energy efficiency
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Pdh
4.7
kW
Tj = -7 °C
Pdh
2.8
kW
Tj = +2 °C
Pdh
1.8
kW
Tj = +7 °C
Pdh
2.7
kW
Tj = +12 °C
Pdh
4.7
kW
Tj = biv
Pdh
4.1
kW
Tj = TOL
Pdh
kW
Tj = -15 °C (if TOL < -20 °C)
T
-7
°C
Min. outdoor air temperature
biv
Pcych
kW
Cycling interval efficiency
Cdh
0.99
-
Max supply temperature
Additional heat
P
0.007
kW
Rated heat output
OFF
P
0.012
kW
TO
P
0.012
kW
Type of energy input
SB
P
0
kW
CK
Variable
Rated airflow (air-water)
L
35 / 51
dB
Nominal heating medium flow
WA
Q
3,248
kWh
Brine flow brine-water or water-water heat
HE
pumps
NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden
AMS 10-6 / HBS 05-6
Warm
Low (35 °C)
ƞ
131
%
s
COPd
1.88
-
COPd
3.26
-
COPd
4.72
-
COPd
6.47
-
COPd
1.88
-
COPd
1.77
-
COPd
-
TOL
-10
°C
COPcyc
-
WTOL
58
°C
Psup
1.2
kW
Electric
3
2,526
m
/h
3
m
/h
3
m
/h
AMS 10