Recommendations; Use Original Spare Parts; Use Original Approved Lubricants; Maintenance Instructions - Pentair Autotrol 255 Installer Manual

Hide thumbs Also See for Autotrol 255:
Table of Contents

Advertisement

9.3.

Recommendations

9.3.1. Use original spare parts

Caution
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, O-ring kit, refill and DLFC.

9.3.2. Use original approved lubricants

Production:
p/n 1014082 (NFO "Chemplex" 862 Silicone Comp.);
spare part:
p/n 42561 (SILICONE LUBRICANT PACK).

9.3.3. Maintenance instructions

Disinfect and clean the system at least once a year or if the treated water has an off-taste or an
unusual odor;
perform a hardness test every year for softeners.
9.4.

Cleaning and maintenance

9.4.1. First steps

Before any cleaning or maintenance procedure, complete the following step :
No.
Caution
These operations need to be performed before any cleaning or maintenance procedure.
A
Unplug the wall-mounted transformer.
B
Shut off water supply or put bypass valve(s) into bypass position.
C
Relieve system pressure before performing any operations.
Ref. MKT-IM-021 / A - 20.02.2019
Installer Manual 255/LOGIX 742-762-764 - Maintenance
Operation
69 / 92

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logix 764Logix 742Logix 762

Table of Contents