Parameter description
P9
Units of measure
P10 Clock mode
P11 Service interval
Remote
P12
regeneration
switch delay
Chlorine
P13
generator options
P14 Refill rate
P15 Draw rate
P16 Reserve type
Initial average or
P17
fixed reserve
Ref. MKT-IM-021 / A - 20.02.2019
Installer Manual 255/LOGIX 742-762-764 - Programming
Default
Range of values
value
0 - 1
1**
0 - 3
1**
0 - 250
3 - 250
0 - 2
1 - 700
1 - 700
0 - 3
0 - 70
Units of
measure
0 = US unit.
N/A
1 = Metric unit.
0 = 12 hour clock, flow rate
displayed.
1 = 24 hour clock, flow rate
displayed.
N/A
2 = 12 hour clock, time of day
displayed.
3 = 24 hour clock, time of day
displayed.
0
Months
Uses 30 days for each months.
Time remote switch must be
60
Seconds
active to start regeneration on
742 - 764 controllers.
0 = no chlorine generator.
1 = salt check only.
0
N/A
2 = generate chlorine and salt
check.
*
gpm x 100 -
*
gpm x 100 -
762/764 controllers only:
0 = variable reserve delayed
regeneration.
1 = fixed reserve delayed
regeneration.
2 = variable reserve delayed
0
N/A
regeneration/fixed reserve
immediate regeneration.
3 = fixed reserve immediate
regeneration.
(Not used with Alternating
systems)
762/764 controllers only:
Depends on value selected for
30
%
P16.
(Not used with Alternating
systems)
Notes
53 / 92