Pentair Autotrol 255 Installer Manual page 51

Hide thumbs Also See for Autotrol 255:
Table of Contents

Advertisement

6.3.2.7 Amount of salt used per regeneration
Set desired salt amount in g/L.
A
Press
.
→ Salt amount flashes.
B
Adjust displayed salt amount with
C
Press
to validate the selection and advance to the next
parameter.
6.3.2.8 Estimated system capacity
Note
The system capacity is displayed in kilograms equivalent CaCO
before a regeneration is necessary.
Note
The system capacity is calculated by the Logix software, using the resin volume and salt
dosage.
Set the estimated system capacity on the controller.
A
Press
.
→ Capacity flashes.
B
Adjust displayed capacity with
C
Press
to validate the selection and advance to the next
parameter.
6.3.2.9 Hardness
Set inlet water hardness at installation site.
A
Press
.
→ Hardness flashes.
B
Adjust displayed hardness with
C
Press
to validate the selection.
→ Basic programming is now complete. The controller will
return you to the normal operation mode.
Ref. MKT-IM-021 / A - 20.02.2019
Installer Manual 255/LOGIX 742-762-764 - Programming
and
.
and
.
and
.
of hardness removed
3
51 / 92

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logix 764Logix 742Logix 762

Table of Contents