Installer Manual 255/LOGIX 742-762-764 - Programming
6.3.1.9 Amount of salt used per regeneration
Set desired salt amount in g/L.
A
Press
.
→ Salt amount flashes.
B
Adjust displayed salt amount with
C
Press
to validate the selection and advance to the next
parameter.
6.3.1.10 Estimated system capacity
Note
The system capacity is displayed in kilograms equivalent CaCO
before a regeneration is necessary.
Note
The system capacity is calculated by the Logix software, using the resin volume and salt
dosage.
Note
This parameter can be overridden for 762 controller and is view only for 742 controller.
Set the estimated system capacity on the controller.
A
Press
.
→ capacity flashes.
B
Adjust displayed capacity with
C
Press
to validate the selection and advance to the next
parameter.
Note
If using the 742 controller, programming is complete. The controller will return you to the
normal operation mode.
6.3.1.11 Hardness (762 controller only)
Set inlet water hardness at installation site.
A
Press
.
→ Hardness flashes.
B
Adjust displayed hardness with
C
Press
to validate the selection.
→ Basic programming is now complete. The controller will
return you to the normal operation mode.