Genie GTH-636 Maintenance Manual page 43

Telehandlers
Hide thumbs Also See for GTH-636:
Table of Contents

Advertisement

September 2016
GTH-1056, GTH-1256, GTH-1544 and GTH-5519:
1
Remove the fuel filler cap from the tank.
2
Check for proper venting.
Result: Air passes through the fuel tank cap.
Proceed to step 4.
Result: If air does not pass through the cap,
clean or replace the cap. Proceed to step 3.
Note: When checking for positive tank cap venting,
air should pass freely through the cap.
Part No. 1272858
Quarterly Maintenance Procedures
3
Using a mild solvent, carefully wash the cap
venting system. Dry using low pressure
compressed air. Repeat this procedure
beginning with step 2.
4
Install the fuel tank cap onto the fuel tank.
Hydraulic Tank Breather Cap - All Models
1
Remove the breather cap from the hydraulic
tank.
2
Check for proper venting. The cap is
pressurized to 3 psi.
Result: Air passes through the breather cap.
Proceed to step 4.
Result: If air does not pass through the cap,
clean or replace the cap. Proceed to step 3.
Note: When checking for positive tank cap venting,
air should pass freely through the cap.
3
Using a mild solvent, carefully wash the cap
venting system. Dry using low pressure
compressed air. Repeat this procedure
beginning with step 2.
4
Install the breather cap onto the hydraulic
tank.
Genie Telehandlers
Maintenance Manual
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gth-844Gth-1544Gth-1056Gth-1256Gth-5519

Table of Contents