Uwatec A700 Maintenance Manual page 11

Step-by-step maintenance procedures
Hide thumbs Also See for A700:
Table of Contents

Advertisement

A700 Step-by-step maintenance procedures.
25. Place the "dive
switch" assembly into the
case. Orient the long-tab
(towards the mouthpiece)
and engage into the "flow
deflector-guides.
Note: The 2 "dive switch"
tabs, engage into the 2
"flow director" guides and
are location specific.
Optional step - only as needed.
If a gap is present
between the "dive switch"
and case, hold pressure
with your index figure as
seen here.
Optional step - only as needed.
While holding pressure,
engage the adjustment
knob and turn
counterclockwise. The
gap will close.
26. The C-clip retainer
land is now accessible.
Orient the retainer clip
"wave top" inward and
snap into place.
27. Press the clip "top &
bottom", to be sure the
new clip is correctly
engaged.
Optional step - only as needed.
Optional step - only as needed.
11
28. Lubricate and install
the 347 inlet tube o-ring.
29. Engage function #7
into the orifice slots.
Screw clockwise until the
lever drops slightly.
This is not an adjustment!
Continued! Lowering the
lever (approximately a ¼
inch) ensures, no
interference when
installing the inhalation
diaphragm, resulting in a
watertight seal. Tap the
lever.
If the disc was removed
from the diaphragm –
return.
Hold and center the disc.
Feed the diaphragm into
the mid section and into
the disc groove.
Inspect...
Be certain the diaphragm
is not distorted.