Setting
Select a UV irradiation pattern to execute.
26
1
Enter the "Intensity Selection" screen.
Setting mode
*1
2
Special intensity
Back
▲ (Back)
Moves to the option immediately above the
current option.
▼ (Next)
Moves to the option immediately below the
current option.
SET (Go)
Calls up the "Intensity Selection" screen.
Select "Intensity Selection" with the "▲" and "▼" buttons, and
press the "SET" button. Then the "Intensity Selection" screen is
called up. (The item is displayed inversely.)
2
With the "▼" button and the "SET" button, select from
among the irradiation patterns: UV1 to UV6.
Any of the patterns UV1 to UV4 can be selected any
Caution:
number of times. (It is not allowed when UV5 or UV6
is selected.)
When UV5 is selected, no other irradiation pattern
can be selected.
When UV6 is selected, no other irradiation pattern
can be selected.
Setting mode
*1
2
Special intensity
Back
▲ (Back)
Terminates "Intensity Selection" and returns to
the "Reference Intensity Setting/Calibration
Setting" screen.
▼ (Next)
Moves the irradiation pattern to 1 to 6.
SET (Set)
Switches the inversely-displayed number
between Selected (with *) and Not Selected
(without *).
Move the highlight bar with the "▼" button to display in inverse
video the irradiation pattern number you want to select. Press
the "SET" button and then "*" will be displayed.
To deselect, press the "SET" button once again. "*" will
disappear.
3
After completion of the selection, press the "▲" button
(Back) to return to the "Intensity Selection" screen.
Intensity selection
3
4
5
6
Next
Go
Intensity selection
3
4
5
6
Next
Set