c – Remove reservoir cap (03).
d – Operate moveable handle (26) several times, in order to advance the ram (01).
e – Press the pressure release lever (20) to retract the ram, discharge oil pressure from the circuit
and return all oil to the reservoir.
f – Repeat points (d - e) fi ve times, to ensure all air bubbles in the hydraulic circuit are purged into
the reservoir.
g – If the oil level is low, top up as directed in paragraph 4.2.
h – Remove all air from reservoir and fi t cap (03).
i – Assemble main handle (25) to tool body.
If the tool continues to malfunction, return the tool for service/repair as detailed in § 7.
26
4.2) Oil top up
Every six months check the oil level in the reservoir. If necessary, to up the oil level to the upper lip of
the reservoir and remove all air from the reservoir, see 4.1, points a, b, c, and e, fi nally, complete with
operations h and i.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fl uid.
Ensure that disposal of used oil is in accordance with current legislation.