Grounding The Tp-752T/Tp-752R - Kramer TP-752T User Manual

2-wire extra range hd transmitter, 2-wire extra range hd receiver
Hide thumbs Also See for TP-752T:
Table of Contents

Advertisement

Because of the extremely high sensitivity of the receivers, there may be crosstalk between
systems within close proximity, and when running cabling from multiple transmitters close
together. To prevent this, in applications employing more than one transmitter, we
recommend using shielded cabling with the shield grounded. When connecting via:
• CAT 5/6: use shielded CAT cable. (The connectors within the
the shield).
• TERMINAL BLOCK: connect shielded cable, with the shield connected to the
ground tabs (see
HD15: no special cautions need to be taken when connecting via standard VGA
cabling. (VGA cable is typically shielded and the connectors within the TP-
752T/TP-752R ground the shield).
4. Set the same baud rate on both devices via the BAUD RATE DIP-switches
(see
Setting the Baud Rate
5. Connect the power adapters to the
), and to the mains electricity (not shown in

Grounding the TP-752T/TP-752R

You can use the grounding screw to earth the chassis of the unit to the building ground
preventing static electricity from impacting the performance of the unit.
Figure 4
defines the grounding screw components.
Figure 4: Grounding Connection Components
To ground the TP-752T/TP-752R, if required:
1. Connect the ring tongue terminal to the building grounding point wire (it is recommended
to use a green-yellow AWG#18 (0.82mm
2. Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the
order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring tongue terminal) into
the grounding screw hole and tighten the screw.
TP-752T / TP-752R – Connecting the TP-752T/TP-752R
Grounding the TP-752T/TP-752R
on page 9).
TP-752T
2
on page
).
8
and
TP-752R
power connectors (
Figure
3).
#
Component Description
1
M3X6 screw
2
1/8" Toothed Lock Washer
3
M3 Ring Tongue Terminal
) wire, crimped with a proper hand-tool).
Kramer Electronics Ltd.
ground
TP-752T/TP-752R
and
and
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tp-752r

Table of Contents