Kramer TP-141 User Manual

Xga/audio line transmitter/receiver
Hide thumbs Also See for TP-141:

Advertisement

Quick Links

K R A ME R E LE CT R O N IC S L TD .
USER MANUAL
MODEL:
TP-141
XGA/Audio Line Transmitter
TP-142
XGA/Audio Line Receiver
P/N: 2900-000419 Rev 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP-141 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kramer TP-141

  • Page 1 K R A ME R E LE CT R O N IC S L TD . USER MANUAL MODEL: TP-141 XGA/Audio Line Transmitter TP-142 XGA/Audio Line Receiver P/N: 2900-000419 Rev 6...
  • Page 3: Table Of Contents

    Recycling Kramer Products Overview About the Power Connect™ Feature Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP) Defining the TP-141 XGA/Audio Line Transmitter Defining the TP-142 XGA/Audio Line Receiver Connecting the TP-141, TP-142 Wiring the TP LINE IN / LINE OUT RJ-45 Connectors...
  • Page 4: Introduction

    Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our...
  • Page 5: Getting Started

    Achieving the Best Performance To achieve the best performance:  Use only good quality connection cables (we recommend Kramer high- performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables) ...
  • Page 6: Safety Instructions

    Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.
  • Page 7: Overview

    50m (150ft) of each other Note: The TP-141 and TP-142 are not compatible with existing Kramer TP units such as the TP-121, TP-122, and so on.
  • Page 8: Shielded Twisted Pair (Stp)/Unshielded Twisted Pair (Utp)

    STP cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STP is intended for analog signals where skewing is not an issue.
  • Page 9: Defining The Tp-141 Xga/Audio Line Transmitter

    Defining the TP-141 XGA/Audio Line Transmitter The TP-141 is an XGA/stereo audio line transmitter that receives an XGA signal and an unbalanced stereo analog audio signal, codes them, and transmits them over CAT 5 cable to a TP-142 receiver. Figure 1 defines the TP-141.
  • Page 10: Defining The Tp-142 Xga/Audio Line Receiver

    Defining the TP-142 XGA/Audio Line Receiver The TP-142 is an XGA/audio line receiver that receives the coded CAT 5 signal transmitted by a TP-141, decodes it and converts it to XGA, stereo analog and S/PDIF digital audio outputs. Figure 2 defines the TP-141.
  • Page 11 ON LED Illuminates when receiving power XGA OUT 15-pin HD Connector Connects to the XGA acceptor LINE IN RJ-45 Connector Connects to the TP-141 AUDIO OUT ANALOG 3.5mm Mini Connects to the analog audio acceptor Jack AUDIO OUT S/PDIF RCA...
  • Page 12: Connecting The Tp-141, Tp-142

    TP-141, TP-142. After connecting your TP-141, TP-142, connect its power and then switch on the power to each device. You can use the TP-141 and TP-142 to configure an XGA / Audio Line-to-Twisted Pair Transmitter and Receiver system. To connect the TP-141 XGA/Audio Line Transmitter with the TP-142 XGA/Audio...
  • Page 13: Figure 3: Connecting The Tp-141, Tp-142

    Set the H SYNC and V SYNC switches, on the underside By default, both switches are set to the left (for negative V SYNC and H SYNC polarity) Figure 3: Connecting the TP-141, TP-142 TP-141, TP-142 - Connecting the TP-141, TP-142...
  • Page 14: Wiring The Tp Line In / Line Out Rj-45 Connectors

    This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors. Figure 4: TP PINOUT EIA /TIA 568B Wire Color Orange / White Orange Green / White Blue Blue / White Green Brown / White Brown TP-141, TP-142 - Connecting the TP-141, TP-142...
  • Page 15: Technical Specifications

    10% to 90%, RHL non-condensing DIMENSIONS: 12.1cm x 7.18cm x 2.42cm (4.76" x 2.83" x 0.95"), W, D, H WEIGHT: 0.3kg (0.67lbs) approx. ACCESSORIES: Power supply Specifications are subject to change without notice at http://www.kramerelectronics.com TP-141, TP-142 - Technical Specifications...
  • Page 17 For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...

This manual is also suitable for:

Tp-142

Table of Contents