Preparation

Install the Truma VarioHeat as specified in the installation
instructions.
Securely screw (2.5 Nm) the mounting bracket (1) onto the
Truma E-Kit with two PT screws (5x14 mm), with a spring
washer in between for each screw (Figure 05 I/II).
I
1 1 1 1
Figure 5

Installation variants

The Truma E-Kit can be installed directly on the Truma VarioHeat
or in the warm air distribution of the Truma VarioHeat.

Mounting on the Truma VarioHeat

Figure 6
Push the Truma E-Kit as far as possible onto the warm air out-
let (2) of the Truma VarioHeat and securely screw the mount-
ing bracket (1) onto the vehicle floor or wall with two screws
(5.5x25 mm). The arrows on the Truma E-Kit indicate the hot
air's direction of flow.
Figure 7

Installation into the warm air distributor

Figure 8
Additional information and notices in the Warm air dis-
tribution section must be followed.
II
1
Truma E-Kit
1
2
Truma E-Kit
1
Truma E-Kit
VR 80

Separate installation space

When installed in the warm air distribution, the Truma E-Kit
can be fitted in a separate installation space. The circulated
air intake of the Truma VarioHeat must be routed through the
installation space of the Truma E-Kit. The circulated air intake
must have one large or several small openings with a total
area of at least 150 cm² between the living compartment (not
the rear storage space) and the installation space. If a grille
(not supplied) is installed, the same requirements must be
complied with for drawing in air in terms of the cross-section-
al area through which flow occurs (150 cm²).
Minimum dimensions of the installation space (in mm)
340
140
Figure 9
The circulating air (U) must flow into the installation space on
the electronics housing (E) side.
Figure 10
Installing the Truma E-Kit in the warm air
distribution
If the Truma E-Kit is installed in the warm air distribution,
a duct adapter (available separately) must be used.
Insert the duct adapter (3) into the Truma E-Kit until both the
catches (4) have engaged in the housing. In addition, the duct
adapter (3) can be securely screwed onto the recesses in the
housing of the Truma E-Kit with two screws (2.9x13 mm).
Figure 11
Insert the duct VR 80 into the warm air outlet (2) of the
Truma VarioHeat and into the Truma E-Kit as far as possi-
ble, and securely screw the mounting bracket (1) onto the
vehicle floor or wall with two screws (5.5 x 25 mm). During
installation, pay attention to the hot air's direction of flow.
Truma E-Kit
360
Truma E-Kit
E
U
4
3
4
EN
9