Copper Ethernet Ports - Siemens Ruggedcom RS416P Installation Manual

Hide thumbs Also See for Ruggedcom RS416P:
Table of Contents

Advertisement

Chapter 4
Communication Ports
Section 4.1

Copper Ethernet Ports

The RUGGEDCOM RS416P supports several 10/100Base-TX Ethernet ports that allow connection to standard
Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ45 male connectors. The RJ45 connectors are
directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more
importantly, create a potential shock hazard that can result in serious injury.
LEDs
Each port features a dedicated LED that indicates the state of the port.
State
Yellow (Solid)
Yellow (Blinking)
Off
Pin-Out
The following is the pin-out for the RJ45 male connectors:
8
Figure 17: RJ45 Ethernet Port Pin Configuration
Specifications
For specifications on the available copper Ethernet ports, refer to
Specifications".
24
Description
Link established
Transmitting/receiving
No link detected
Pin
1
Name
1
RX+
2
RX-
3
TX+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
TX-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Section 5.4, "Copper Ethernet Port
RUGGEDCOM RS416P
Installation Guide
Description
Receive Data+
Receive Data-
Transmit Data+
Transmit Data-