Rohs; Other Approvals; Emc And Environmental Type Tests - Siemens Ruggedcom RS416P Installation Manual

Hide thumbs Also See for Ruggedcom RS416P:
Table of Contents

Advertisement

Chapter 6
Certification
Section 6.1.7

RoHS

This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
• China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
view/109738831.
Section 6.1.8

Other Approvals

This device meets the requirements of the following additional standards:
• IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
• IEC 61850-3
Communication Networks and Systems for Power Utility Automation - Part 3: General Requirements
• IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments
Section 6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS416P has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
42
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
https://support.industry.siemens.com/cs/ww/en/
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth
ground ports
Signal ports
DC Power ports
± 2 kV line-to-earth, ± 1 kV line-to-line
Installation Guide
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2 kV
RUGGEDCOM RS416P
Severity Levels
4
4
a
Note
a
Note
4
4
4
3
3
RoHS

Advertisement

Table of Contents
loading

Table of Contents