RUGGEDCOM RS416P
Installation Guide
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
•
Section 1.5.1, "Supported Fiber Optic Cables"
Section 1.5.1
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Cable Type
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
Section 1.6
Precision Time Protocol (PTP) Support
The Precision Time Protocol (PTP) module adds the ability to provide time synchronization via Ethernet using the
Precision Time Protocol (PTP) and Network Time Protocol (NTP), and to synchronize with an external IRIG-B source.
The PTP module features BNC ports for TTL IN and TTL OUT. It also includes an LED to indicate when
synchronization has been achieved.
NOTE
The PTP module can only be installed in slot 5. For more information, refer to
Communication
Supported Fiber Optic Cables
Modal Bandwidth
Wavelength (nm)
(MHz·km)
850
1300
850
1300
850
1300
850
1300
Ports.
100Base-FX
200
—
500
2000
500
—
500
2000
1500
—
500
2000
3500
—
500
2000
Introduction
Distance (m)
1000Base-SX
10GBase-SR
275
33
—
—
550
82
—
—
550
300
—
—
550
400
—
—
Chapter 4,
Chapter 1
5