RUGGEDCOM RS416P
Installation Guide
Communication Ports
The RUGGEDCOM RS416P can be equipped with various types of communication ports to enhance its abilities
and performance.
Each communication port type has a specific place in the RUGGEDCOM RS416P chassis.
Figure 17: Port Assignment
1. Slot 1
2. Slot 2
3. Slot 3
Slot
1 to 4
5
6
The following sections describe the available ports:
•
Section 3.1, "Copper Ethernet Ports"
•
Section 3.2, "Fiber Optic Ethernet Ports"
•
Section 3.3, "Serial Ports"
•
Section 3.4, "BNC Ports"
•
Section 3.5, "Connecting Multiple RS485 Devices"
Section 3.1
Copper Ethernet Ports
The RS416P supports several 10/100Base-TX Ethernet ports that allow connection to standard Category 5
(CAT-5) unshielded twisted-pair (UTP) cables with RJ45 male connectors. The RJ45 connectors are directly
connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
Copper Ethernet Ports
1
2
4. Slot 4
5. Slot 5
6. Slot 6
Type
Serial Ports
Fast Ethernet (10/100Base-TX PoE, 10Base-FL or 10/100Base-FX) or BNC Ports
Fast Ethernet (10/100Base-TX PoE, 10Base-FL or 10/100Base-FX)
3
5
4
6
Chapter 3
Communication Ports
19